HYPANOPLY Anti-Graffiti
HYtech PANOPLY GEL external thermal insulation system with graffiti removal capabilities (p.9). Layers as drawn on the p.10 diagram, finished with HYGRAFFITI PRO SHIELD permanent anti-graffiti varnish.
FacadesExternal walls
| Layer | Products | Consumption |
|---|---|---|
| Waterproofing zone Optional: in the waterproofing zone at the base of the wall, as shown on the p.10 diagram | 1.2 kg/m²/mm 1.5 kg/m²/mm | |
| Quartz adhesion primer on the substrate Optional: shown on the p.10 diagram on the masonry; the catalogue states no condition, so check the substrate per the primer TDS | 250–350 g/m² 200–300 g/m² | |
| Adhesive for bonding the thermal insulation panels | 4–6 kg/m² 4–6 kg/m² 3–4 kg/m² 4–6 kg/m² 4–6 kg/m² 4–6 kg/m² 12–15 kg/m²/cm | |
| Thermal insulation panels (polystyrene, mineral wool etc.) | data sheet | |
| Anchors (PRODOM / HYDOM) | data sheet data sheet data sheet | |
| Corner beads Optional: at external corners and edges | data sheet | |
| Water drip profiles Optional: at vertical-to-horizontal transitions such as balconies and lintels | data sheet | |
| Basic armored layer (base coat) | 4–6 kg/m² 4–6 kg/m² 4–6 kg/m² 4–6 kg/m² 4–6 kg/m² 12–15 kg/m²/cm | |
| Fiberglass mesh (PRODOM or HYDOM) | 1.1 m/m² 1.1 m/m² | |
| Quartz adhesion primer for final coats | 250–350 g/m² 180–280 g/m² | |
| Final decorative layer | 2–3.5 kg/m² 2–3.5 kg/m² 1.5 kg/m² 2–2.5 kg/m² | |
| Adhesion primer for the anti-graffiti varnish Optional: according to the final coating type (suggested particularly on organic plasters) | 19–24 m²/kg | |
| Protection varnish | 5–6 m²/kg |
Notes on this system
- The p.10 diagram names 'FL100 ST' without a variant; mapped to the FL100 ST variants whose text covers board bonding (adhesive layer) or the mesh layer (base coat).