HYPANOPLY Impact
HYtech PANOPLY GEL anti-vandal external thermal insulation system with excellent impact resistance (p.9): HYDOM IMPACT NET (330 g/m²) embedded in HYPANOPLY GEL mortar, which is the recommended adhesive for the net (p.19).
FacadesExternal walls
| Layer | Products | Consumption |
|---|---|---|
| Waterproofing zone Optional: in the waterproofing zone at the base of the wall, as shown on the p.10 diagram | 1.2 kg/m²/mm 1.5 kg/m²/mm | |
| Quartz adhesion primer on the substrate Optional: shown on the p.10 diagram on the masonry; the catalogue states no condition, so check the substrate per the primer TDS | 250–350 g/m² 200–300 g/m² | |
| Adhesive for bonding the thermal insulation panels | 4–6 kg/m² | |
| Thermal insulation panels (polystyrene, mineral wool etc.) | data sheet | |
| Anchors (PRODOM / HYDOM) | data sheet data sheet data sheet | |
| Corner beads Optional: at external corners and edges | data sheet | |
| Water drip profiles Optional: at vertical-to-horizontal transitions such as balconies and lintels | data sheet | |
| Basic armored layer (base coat) | 4–6 kg/m² | |
| Anti-vandal fiberglass impact net | 1.1 m/m² | |
| Quartz adhesion primer for final coats | 250–350 g/m² 180–280 g/m² | |
| Final decorative layer | 2–3.5 kg/m² 2–3.5 kg/m² 1.5 kg/m² 2–2.5 kg/m² |
Notes on this system
- No dedicated diagram for this variant; layers other than those named for it on pp.9 and 19 are taken from the p.10 HYPANOPLY diagram.
- The catalogue does not say whether a standard 160 g/m² mesh is also needed alongside the impact net.
- The p.10 diagram shows a 'Starting guide' (starter profile) at the base of the boards, but no such product is catalogued; it is not represented as a layer.